Stellar Installation into a DT Atom
Required Tools
- 3/16” Allen wrench
Required Parts
- 2x DT Stellar
- 8x Atom Gemini Mounting Screws
- DT Atom*
- 2x Atom Pins
*DT Atoms manufactured prior to 2020 use a larger pin format compatible with the DT Photon (Mark I); contact DT about new pins and pin receivers that are compatible with the DT Stellar.
Steps
Remove the 4 Atom/Gemini Mount 10-32 ⅜” socket head cap screws from each Stellar unit.
A DT Atom Pin has two detents for aligning the angle of a DT Stellar when mounted to a DT Atom. Because there are two detents, each DT Stellar can be used on either side of a DT Atom. Position the detents so they are towards the back of each Stellar. Replace the four Atom/Gemini Mount screws.
Loosen the Tightening Knob of the Mounting Block on the Atom arm.
Insert Atom Pin into Mounting Block on the Atom until seated against the Mounting Block.
Rotate Stellar on mounting pin till detent locks Stellar into the correct angle.
Tighten the Tightening Knob of the Mounting Block to secure the Stellar in place.
For Atom units made in 2024 and after, a channel inside the arms of the Atom is included to house power and ethernet cables. On older DT Atoms, cables should be routed along the back of the arm and secured with Velcro straps.